Search results for "cataract surgery"

showing 10 items of 82 documents

Objective Assessment of Nuclear and Cortical Cataracts through Scheimpflug Images: Agreement with the LOCS III Scale.

2016

Purpose To assess nuclear and cortical opacities through the objective analysis of Scheimpflug images, and to check the correlation with the Lens Opacity Classification System III (LOCS III). Methods Nuclear and cortical opacities were graded according to the LOCS III rules after pupil dilation. The maximum and average pixel intensity values along an elliptical mask within the lens nucleus were taken to analyse nuclear cataracts. A new metric based on the percentage of opaque pixels within a region of interest was used to analyse cortical cataracts. The percentage of opaque pixels was also calculated for half, third and quarter areas from the region of interest’s periphery. Results The maxi…

0301 basic medicineMaleScheimpflug principlelcsh:MedicineDiagnostic Techniques OphthalmologicalSeverity of Illness IndexMachine Learning0302 clinical medicineMedicine and Health Scienceslcsh:ScienceOptical PropertiesLens (Anatomy)PhysicsAged 80 and overMultidisciplinaryApplied MathematicsSimulation and ModelingOphthalmic ProceduresCataract SurgeryMiddle AgedOptical LensesOptical EquipmentPhysical SciencesEngineering and TechnologyFemaleAnatomyAlgorithmsResearch ArticleOpacityAdultDiagnostic Imagingmedicine.medical_specialtyComputer and Information SciencesScale (ratio)OpacityImaging TechniquesOcular AnatomyMaterials ScienceMaterial PropertiesEquipmentSurgical and Invasive Medical ProceduresImage AnalysisResearch and Analysis MethodsLens nucleusCataract03 medical and health sciencesMachine Learning AlgorithmsYoung AdultCataractsRegion of interestOcular SystemArtificial IntelligenceOphthalmologymedicineHumansAgedPixelCataractslcsh:RBiology and Life SciencesCorrectionLens Nucleus CrystallineLens Cortex Crystallinemedicine.diseaseIntensity (physics)Ophthalmology030104 developmental biologyLens DisordersCase-Control Studies030221 ophthalmology & optometryEyesCognitive Sciencelcsh:QHeadMathematicsNeurosciencePloS one
researchProduct

Changes in tear film metrics and ocular signs induced by different types of refractive correction in an aging population

2018

La integridad de la superficie ocular, en otras palabras, su capacidad para responder adecuadamente a los desafíos ambientales, depende de la integración adecuada de la información desde la superficie ocular, la transmisión de la señal creada hacia el cerebro y la generación de una respuesta, que modulará la función secretora así como la inmunidad local de la superficie ocular. Es fácilmente comprensible que cualquier alteración de uno de los tres pasos de este ciclo cerrado pueda desencadenar una respuesta inapropiada y desequilibrar aún más los mecanismos compensatorios que tienen lugar en la superficie ocular. La unidad funcional de la lágrima se puede definir como un conjunto de estruct…

:FÍSICA [UNESCO]Dry eye aging presbyopia cataract surgery refractive surgeryUNESCO::FÍSICA
researchProduct

Evaluation of the practicality of optical biometry and applanation ultrasound in 253 eyes

2003

Abstract Purpose To evaluate the percentage of eyes that could not be measured using optical biometry and ultrasound applanation and the reasons. Setting Department of Ophthalmology, Johannes Gutenberg-University Hospital, Mainz, Germany. Methods Optical biometry (IOLMaster®, Carl Zeiss Meditec AG) and A-scan ultrasound biometry were performed consecutively in 253 eyes scheduled for cataract surgery the next day. Lens opacities were evaluated with the Opacity Lensmeter (Interzeag), and a slitlamp examination and measurement of visual acuity were performed. The 2 techniques were compared in terms of the rate of and reasons for primary measurement failure. Results Measurement with the IOLMast…

AdultBiometryVisual acuityAdolescentLightPseudophakiagenetic structuresmedicine.medical_treatmentEye diseaseVision DisordersVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalEyeRefraction OcularCataractOptical biometryLens Implantation IntraocularHumansMedicineChildAgedUltrasonographyAged 80 and overLenses Intraocularbusiness.industryUltrasoundMiddle AgedCataract surgerymedicine.diseaseeye diseasesSensory SystemsOptical axisOphthalmologyInterferometryChild PreschoolOptometrySurgerysense organsmedicine.symptombusinessPseudophakiaJournal of Cataract and Refractive Surgery
researchProduct

Healon5 versus Viscoat during cataract surgery: intraocular pressure, laser flare and corneal changes

2000

Background: The use of a viscoelastic substance facilitates cataract surgery. Healon 5 is a new viscoelastic product with special rheological properties. We evaluated the postoperative effect of Viscoat and Healon5 on intraocular pressure (IOP), central corneal thickness (CCT), endothelial cell counts and laser flare. Methods: Forty-eight eyes of 48 patients undergoing routine phacoemulsification followed by foldable IOL implantation were enrolled. Either Healon5 or Viscoat was used according to a block- randomization scheme. The aspiration technique was standardized. IOP, CCT, endothelial cell counts and laser flare were compared pre- and postoperatively. Statistical analysis was performed…

AdultMaleIntraocular pressuremedicine.medical_specialtyRandomizationgenetic structuresmedicine.medical_treatmentEye diseaseCell CountIntraocular lensAqueous HumorPhotometryCellular and Molecular NeuroscienceLens Implantation IntraocularCorneaOphthalmologymedicineHumansProspective StudiesHyaluronic AcidIntraocular PressurePhacoemulsificationbusiness.industryChondroitin SulfatesEndothelium CornealPhacoemulsificationCataract surgerymedicine.diseaseeye diseasesSensory SystemsDrug CombinationsOphthalmologymedicine.anatomical_structureQuartileFemalesense organsbusinessChondroitinGraefe's Archive for Clinical and Experimental Ophthalmology
researchProduct

Intraocular pressure after small incision cataract surgery: temporal sclerocorneal versus clear corneal incision.

2001

To compare intraocular pressure (IOP) after phacoemulsification and foldable intraocular lens (IOL) implantation using a temporal sclerocorneal or clear corneal incision.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.One hundred patients (100 eyes) with cataract having phacoemulsification with posterior chamber IOL implantation were randomly assigned to receive a temporal sclerocorneal or clear corneal tunnel incision. Intraocular pressure was measured preoperatively and 6 hours, 1, 2, and 3 days, and 5 months postoperatively. Statistical significance was determined by nonparametric group comparisons using 2-sample random Wilcoxon tests.Six hours postoperatively,…

AdultMaleIntraocular pressuremedicine.medical_specialtygenetic structuresmedicine.medical_treatmentIntraocular lensCataractCorneaLens Implantation IntraocularCorneaOphthalmologymedicineHumansMinimally Invasive Surgical ProceduresProspective StudiesSclerocorneaIntraocular PressureAgedAged 80 and overPhacoemulsificationbusiness.industryPhacoemulsificationCataract surgeryMiddle Agedmedicine.diseaseeye diseasesSensory SystemsSurgeryScleraOphthalmologymedicine.anatomical_structureSurgeryFemalesense organsbusinessSurgical incisionScleraJournal of cataract and refractive surgery
researchProduct

Biaxial Microincision versus Coaxial Small-Incision Clear Cornea Cataract Surgery

2005

Objective To compare clinical outcomes of biaxial microincision (1.5 mm) and coaxial small-incision (2.75 mm) clear cornea cataract surgery. Design Randomized controlled clinical trial. Participants Seventy eyes of 70 patients were examined at a German university eye hospital. Intervention The 70 patients (70 eyes) were assigned randomly (1:1) to a biaxial or conventional coaxial incision group. Both groups underwent phacoemulsification using pulsed ultrasound energy with variable duty cycles, followed by microincision intraocular lens implantation. Main Outcome Measures Best-corrected visual acuity (BCVA), astigmatism, laser flare photometry value, effective phacoemulsification time (EPT),…

AdultMaleMicrosurgerymedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityCell CountIntraocular lensAstigmatismCorneaLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreAgedAged 80 and overPhacoemulsificationbusiness.industryEndothelium CornealAstigmatismPhacoemulsificationMiddle AgedCataract surgerymedicine.diseaseOphthalmologyFemalemedicine.symptomCoaxialbusinessSurgical incisionOphthalmology
researchProduct

Optical coherence tomography of macular thickness after biaxial vs coaxial microincision clear corneal cataract surgery

2009

PURPOSE To evaluate macular thickness changes after biaxial microincision versus coaxial small incision cataract surgery using optical coherence tomography (OCT). METHODS This prospective, randomized, marked study comprised 70 patients (70 eyes) undergoing biaxial microincision surgery or conventional coaxial phacoemulsification. Patients were evaluated by Stratus OCT preoperatively and 1 day, 4 weeks, and 8 weeks postoperatively. Best-corrected visual acuity (BCVA), phacoemulsification power, and effective phacoemulsification time (EPT) were evaluated. RESULTS In the biaxial group, median foveal thickness changed from 160 microm preoperatively to 168 microm 8 weeks postoperatively (p=0.018…

AdultMaleMicrosurgerymedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityFoveal thicknessMacular EdemaCornea03 medical and health sciencesPostoperative Complications0302 clinical medicineOptical coherence tomographyOphthalmologyBlood-Retinal BarrierHumansMedicineMacula LuteaProspective StudiesIntraoperative ComplicationsAgedAged 80 and overPhacoemulsificationmedicine.diagnostic_testbusiness.industrySignificant differenceGeneral MedicinePhacoemulsificationMiddle AgedCataract surgeryeye diseasesOphthalmologySmall incision030221 ophthalmology & optometryFemalesense organsmedicine.symptomCoaxialbusinessTomography Optical Coherence030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

Incidence of posterior vitreous detachment after cataract surgery

2009

Purpose To report the incidence of posterior vitreous detachment (PVD) after uneventful state-of-the-art small-incision phacoemulsification with implantation of a posterior chamber intraocular lens (PC IOL). Setting Department of Ophthalmology, Ludwigshafen Hospital, Ludwigshafen, Germany. Methods This prospective study evaluated the vitreous status of eyes by biomicroscopic examination, indirect binocular ophthalmoscopy, and B-scan ultrasonography before planned cataract surgery. Patients with the posterior vitreous attached were included for follow-up and examined 1 week, 1 month, and 1 year after uneventful phacoemulsification with PC IOL implantation. The preoperative prevalence and pos…

AdultMaleMicrosurgerymedicine.medical_specialtygenetic structuresEye diseasemedicine.medical_treatmentVitreous DetachmentPosterior vitreous detachmentOphthalmoscopyPostoperative ComplicationsLens Implantation IntraocularGermanyOphthalmologymedicineHumansProspective StudiesDioptreAgedUltrasonographyAged 80 and overPhacoemulsificationmedicine.diagnostic_testbusiness.industryIncidencePhacoemulsificationMiddle AgedMicrosurgeryCataract surgerymedicine.diseaseeye diseasesSensory SystemsSurgeryVitreous DetachmentOphthalmologyFemaleSurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Five-year functional outcomes and vault of -20 diopter myopic phakic intraocular lens implantation.

2015

Purpose To evaluate refractive and visual outcomes and complications associated with phakic intraocular lens (pIOL) implantation to correct high myopia. Settings Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective observational case series. Methods Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), refraction, vault, and adverse effects were evaluated after 5 years with Visian ICMV4 pIOL. Results Mean spherical equivalent (SE) dropped from −18.32 ± 2.37 diopters (D) preoperatively to −0.88 ± 0.52D 5 years postoperatively; 61% of eyes were within ±0.75 D of the target. The mean Snellen decimal CDVA and UDVA were 0.73 ± 0.23 and 0…

AdultMalePhakic Intraocular LensesVisual acuityAnterior subcapsular cataractDistance visual acuityBiometrygenetic structuresmedicine.medical_treatmentVisual AcuityPhakic intraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularAnterior Eye SegmentmedicineMyopiaHumansDioptreRetrospective StudiesEfficacy indexbusiness.industryHigh myopiaCataract surgeryeye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessTomography Optical CoherenceFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Prevalence of cataract after collagen copolymer phakic intraocular lens implantation for myopia, hyperopia, and astigmatism

2015

Purpose To evaluate the prevalence of cataract after Implantable Collamer Lens phakic intraocular lens (pIOL) implantation with different models at different ages and for different refractive powers. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective nonrandomized clinical study. Methods The pIOL (models V4, V4b, or V4c) was implanted in all cases. Results The study included 3420 eyes (1898 patients). The mean patient age at surgery was 31.2 years ± 6.4 (SD) (range 18 to 50 years) and the mean spherical refractive error, −7.27 ± 5.24 diopters (D) (range −26.5 to 12.5 D). Twenty-one eyes (0.61%) of 15 patients had pIOL explantation (all model V4) because c…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyAdolescentgenetic structuresPolymersmedicine.medical_treatmentVisual AcuityAstigmatismMyopia/hyperopiaPhakic intraocular lensCataractLens Implantation IntraocularCataractsOlder patientsPatient ageOphthalmologyMyopiaPrevalencemedicineHumansDevice RemovalDioptreRetrospective Studiesbusiness.industryAstigmatismMiddle AgedCataract surgerymedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaSpainFemaleSurgeryCollagensense organsbusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct